Contact Person : Eric
Phone Number : +86 18038000078
WhatsApp : +8618038000078

Hospital Use 500L/Hour 2 Stage RO System With EDI Pure Water Treatment Plant

Place of Origin Shenzhen,China
Brand Name HongJie
Certification ISO 14001,ISO 9001,CE,EPA
Model Number HJ-UPWHo500L
Minimum Order Quantity >=1sets
Price US$2105~US$2200
Packaging Details export standard wooden case
Delivery Time 1-7working days(depand on raw materials stocking)
Payment Terms L/C,T/T,D/P,Western Union
Supply Ability >300sets/month

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Flow Rate 500l/h(Customizable) Water Quality Conductivity<≤1.3 μS/cm
Core Process Double-pass Reverse Osmosis + EDI Core Components RO Membrane Modules, EDI Units
Operation Mode Fully Automated Product Features Stable Water Quality Output, Low Operational Costs
After-Sales Service 24/7 Technical Support, 2-Year Maintenance Industry Standard GMP
Highlight

2 Stage RO System With EDI

,

500L/Hour 2 Stage RO System

,

Hospital Use Pure Water Treatment Plant

Leave a Message
Product Description

I. Equipment Overview

In hospital settings, ultrapure water plays a critical role in various areas, including medical equipment operation (hemodialysis machines, cleaning equipment in sterilization supply centers, imaging equipment), testing and analysis (biochemical analysis, microbial culture), and formulation production (large-volume parenteral solutions, topical formulations). Hospitals have extremely stringent quality requirements for ultrapure water, which must typically comply with relevant pharmacopoeia standards (such as the Chinese Pharmacopoeia) and industry regulations (microbial indicators, endotoxin indicators, chemical indicators).

 

II. Process 

Raw Water → Raw Water Pressure Pump → Multimedia Filter → Activated Carbon Filter → Water Softener → Precision Filter → Primary RO → pH Adjustment → Intermediate Water Tank → Secondary RO → Intermediate Water Tank → Intermediate Water Pump → EDI System → Purified Water Tank → Pure Water Pump → UV Sterilizer → Microporous Filter →Pasteurization → Water Point

 

III. Specifications 

Indicator Type Specific Indicator Control Requirement Purpose
Microbial Indicator Total microbial colony count per 100 mL ≤1 CFU/100mL Prevent contamination of medical equipment, drugs, and test samples
Endotoxin Indicator Endotoxin content ≤0.25 EU/mL (Stricter requirements for ultrapure water used in injection production and hemodialysis) Ensure medical safety and avoid adverse reactions
Chemical Indicator Conductivity at 25°C ≤1.3 μS/cm Reflect the content of ionic impurities
Total Organic Carbon (TOC) ≤500 ppb Avoid organic matter interfering with medical processes