Contact Person : Eric
Phone Number : +86 18038000078
WhatsApp : +8618038000078

50m3/H Automated Ultrapure Water Systems With Electrodeionization Module

Place of Origin Shenzhen,China
Brand Name HongJie
Certification ISO 14001,ISO 9001,CE,EPA
Minimum Order Quantity >=1sets
Price US$110000~US$115000
Packaging Details export standard wooden case
Delivery Time 1-7working days(depand on raw materials stocking)
Payment Terms L/C,D/P,T/T,Western Union
Supply Ability >300sets/month

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Flow Rate 50m³/h(Customizable) Water Quality Conductivity<≤1.3 μS/cm(25°C)
Core Process Double-pass Reverse Osmosis + EDI Core Components RO Membrane Modules, EDI Units
Operation Mode Fully Automated Product Features Stable Water Quality Output, Low Operational Costs
After-Sales Service 24/7 Technical Support, 2-Year Maintenance Industry Standard GMP
Microorganism < 10 CFU/100mL TOC ≤500 Ppb
Highlight

50m3/H ultrapure water systems

,

Automated ultrapure water systems

,

50m3/H pure water treatment plant

Leave a Message
Product Description

Thorough Purification 50 m³/h sterile preparation Water Purifier Filter with Electrodeionization Module

 

I.Overview
Ultrapure water (UPW) plays a critical role in the preparation of sterile formulations (such as injectables, eye drops, and biopharmaceuticals), with its extremely high purity being a core element in ensuring product safety, efficacy, and compliance. From system design (compliant with ASME BPE standards), real-time monitoring, to strict GMP management, every step must ensure that water quality consistently meets the “zero-tolerance” standards for microbial/chemical contamination.

 

II.Process
Raw Water → Pre-treatment → Double-stage RO Reverse Osmosis → Continuous Electro-deionization (EDI) → Dual-wavelength UV Disinfection → Membrane Degassing Unit → High-temperature Distillation → High-temperature Recirculation Distribution → Final Filtration

 

III.Key Quality Indicators (Real - time Monitoring)

Parameter Pharmacopoeia Standard Actual Control Requirement
Microorganism < 10 CFU/100mL < 1 CFU/100mL
Endotoxin ≤0.25 EU/mL ≤0.001 EU/mL
Conductivity (25°C) ≤1.3 μS/cm ≤1.0 μS/cm
TOC ≤500 ppb ≤50 ppb
 

IV.Core Functions: As a Solvent or Carrier  
Dissolving Active Pharmaceutical Ingredients (APIs): UPW serves as the primary solvent for dissolving sterile APIs or lyophilized powders.  
Dilution and Volume Adjustment: Used to precisely adjust formulation concentration to target specifications.  
Cleaning Critical Components: Equipment directly contacting pharmaceutical solutions, such as formulation tanks, piping, and filters, must be cleaned with UPW to prevent contamination.

 

V.Optimization for Special Applications  
Biologics: Incorporate TFF (Tangential Flow Filtration) to remove nucleases.  
ADC (Antibody-Drug Conjugates): Heavy metal control (Cu²⁺ < 0.1 ppb).  
mRNA Vaccines: DNase/RNase-free certification (terminal ultrafiltration material selection).

 

VI.Here is a guideline for you to get a proper quotation

Tell us the raw water/source of water(tap water, well water, or sea water, etc)
Provide water analysis report(TDS , conductivity, or resistivity, etc)
Required production capacity( 5m³/H, 50m³/H,or 500m³/H, etc)
What's the pure water used for( industrial,Food and Beverage,or agriculture, etc )